Tags: enviromon

A graph from EnviroMon

28/03/08 | by Jeff [mail] | Categories: Temperature

It's about time we showed some actual results from EnviroMon, so here is a typical graph. I grabbed this directly from today's web page at http://www.picotech.com/dynamic/index.html. It shows nicely how the temperatures in the board room (upstairs in the most exposed corner of the building) and the dispatch area (with its large roller shutter and double doors) drop overnight much more than in other parts of the building.


The EnviroMon dynamic web pages are now live

05/02/08 | by Jeff [mail] | Categories: News

We have now wired up the whole building with EnviroMon to monitor temperature, humidity and power consumption. The results can be viewed online at www.picotech.com/dynamic. The power consumption is very high. On a weekday we are averaging 100A from each of the three phases. Even when you account for lower power consumption at the weekend, this equates to an electricity bill for the year of around £52,000 !

We also gave the air conditioning system its first service of the year today. The engineers replaced the air filters in all areas. They also switched off the heating in the small unused offices in the marketing and admin area.

11:30am

  • A temperature sensor was added.

Approx 14:50

  • The temperature in the development area was reduced from 21 C to 18 C.
  • The thermostat for the preheat in the plant room has been reduced from 20 C to 10 C.
  • The timers have been changed to heat from 7am to 5pm.
  • Air conditioning downstairs turned on.

Now that the building is monitored, we will be working to reduce our power consumption, most of which comes from the HVAC. The blocked filters that we have replaced today, along with some simple tweaks to the timing, should save £1000s.

These are the new and old air filters. Dark roast coffee, anyone?


Follow Pico Technology's journey from energy hog to energy saver.

Search

Blogroll

  • News
    • April Fool!
    • Energy-saving coating
    • The energy-saving project has begun!
    • The EnviroMon dynamic web pages are now live
  • Temperature
    • 7-day timers for small heaters
    • A graph from EnviroMon
    • A misplaced sensor causing erratic temperatures
    • Air con current test; redundant fans
    • Another poorly insulated room
    • Board room temperature sensor
    • Development area temperature
    • Even buildings have fan belts
    • Keeping the servers cool
    • Kitchen heater
    • More air conditioning changes upstairs
    • Production temperature
    • Production temperature
    • Production temperature again
    • Production temperature again
    • Temperature sensor moved
    • Various adjustments
  • Lighting
    • Another £100 per year saved
    • Going down
    • How to save 6926 kWh per year
    • Saving £1000 per year on lighting
  • Energy
    • Increased consumption
    • Latest meter readings
    • Meter readings still falling
    • Meter readings update
    • Meter readings: lower still
    • Monitor power usage
    • New TFT monitors
    • Our bills are going down at last!
    • Plug-in energy meters